Logo

PMMA Denture Base Materials: A Review on Mechanical Properties of Conventional and CAD/CAM Milled Materials

المؤلفون
  • Fathie Kundie

    Department of Dental Technology, College of Medical Technology, Benghazi, Libya,
    Author
  • Zainal Arifn Ahmad

    School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia,14300 Nibong Tebal, Penang, Malaysia
    Author
الكلمات المفتاحية:
Polymethyl Methacrylate; Denture Bbase; Complete Denture; Conventional PMMA; Milled CAD/CAM; Mechanical Properties
الملخص

Polymethyl methacrylate (PMMA) has been utilized for the construction of dental prostheses, i.e. complete and partial dentures, artificial teeth, obturators, removable orthodontic appliances, provisional crowns, and for the repairing of broken prostheses. For completely edentulous patients, complete dentures (CDs) remain the primary treatment option. Conventional heat-cured PMMA (C-PMMA) is used to fabricate the CDs. However, this method has several disadvantages, such as inadequate mechanical properties, residual monomer content, poor stability, reduction in retention and occlusal accuracy. Recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been utilized for CDs fabrication. Therefore, this review makes a comparison between CAD/CAM PMMA and C-PMMA with regards to their mechanical properties i.e. fracture strength, flexural strength, flexural modulus, elastic modulus, impact strength, and hardness. The Google Scholar, PubMed/Medline, and Science Direct databases were searched for studies written in English and published between 2013 and 2026. The keywords used were conventional heat-cured PMMA dentures, heat-polymerized PMMA, CAD/CAM PMMA dentures, mechanical properties, and a combination of two or more of them. The search yielded 109 articles. Forty-nine studies have been included in this review. Results showed that the CAD/CAM PMMA dentures show superior mechanical properties compared to the C-PMMA. The use of CAD/CAM PMMA resins could increase denture longevity and improve clinical performance. Additional studies in clinical use are needed to complement these results. Therefore, further studies on the physico-chemical properties are needed to achieve a comprehensive evaluation of these materials

التنزيلات
تنزيل البيانات ليس متاحًا بعد.
السيرة الشخصية للمؤلف
  1. Zainal Arifn Ahmad، School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia,14300 Nibong Tebal, Penang, Malaysia

    srzainal@usm.my

المراجع

Abdulla, M. A., Ali, H., & Jamel, R. S. (2020). CAD-CAM technology: a literature review. Al-Rafidain Dental Journal, 20(1), 95-113.

Abualsaud, R., & Gad, M. M. (2022). Flexural Strength of CAD/CAM Denture Base Materials: Systematic Review and Meta-analysis of: In-vitro: Studies. Journal of International Society of Preventive and Community Dentistry, 12(2), 160-170.

Adsare, P., Patil, A., Raj, P., Puranik, S., Menga, R., & Rajendra, K. (2024). Comparison and Evaluation of Fracture Toughness of Milled, 3D-Printed, and Conventional Polymethyl Methacrylate: An In Vitro Study. Journal of Pharmacy and Bioallied Sciences, 16(Suppl 1), S484-S487.

Al-Dwairi, Z. N., Tahboub, K. Y., Baba, N. Z., & Goodacre, C. J. (2020). A comparison of the flexural and impact strengths and flexural modulus of CAD/CAM and conventional heat‐cured polymethyl methacrylate (PMMA). Journal of Prosthodontics, 29(4), 341-349.

Al-Dwairi, Z. N., Tahboub, K. Y., Baba, N. Z., Goodacre, C. J., & Özcan, M. (2019). A comparison of the surface properties of CAD/CAM and conventional polymethylmethacrylate (PMMA). Journal of Prosthodontics, 28(4), 452-457.

Al Essa, H. A. (2019). CAD/CAM in prosthodontics: A gate to the future. International Journal of Applied Dental Sciences, 5(3), 394-397.

Al Taweel, S. M., Al Fouzan, A., Al-Otaibi, H. N., Labban, N., & AlShehri, H. A. (2021). Thermal-cycling, simulated brushing, and beverages induced color changes and roughness of CAD/CAM poly (methyl methacrylate) denture resins. Materials Research Express, 8(12), 125401.

Alageel, O., Wazirian, B., Almufleh, B., & Tamimi, F. (2019). Fabrication of dental restorations using digital technologies: techniques and materials. Digital Restorative Dentistry: A Guide to Materials, Equipment, and Clinical Procedures, 55-91.

Alhallak, K., Hagi-Pavli, E., & Nankali, A. (2023). A review on clinical use of CAD/CAM and 3D printed dentures. British Dental Journal, 1-5.

Alla, R. K., Sajjan, S., Alluri, V. R., Ginjupalli, K., & Upadhya, N. (2013). Influence of fiber reinforcement on the properties of denture base resins.

Almusallam, S. M., & AlRafee, M. A. (2020). The prevalence of partial edentulism and complete edentulism among adults and above population of Riyadh city in Saudi Arabia. Journal of Family Medicine and Primary Care, 9(4), 1868.

Alqutaibi, A. Y., Baik, A., Almuzaini, S. A., Farghal, A. E., Alnazzawi, A. A., Borzangy, S., . . . Zafar, M. S. (2023). Polymeric Denture Base Materials: A Review. Polymers (Basel), 15(15).

Alzayyat, S. T., Almutiri, G. A., Aljandan, J. K., Algarzai, R. M., Khan, S. Q., Akhtar, S., . . . Gad, M. M. (2022). Effects of SiO2 incorporation on the flexural properties of a denture base resin: an in vitro study. European Journal of Dentistry, 16(01), 188-194.

Anadioti, E., Musharbash, L., Blatz, M. B., Papavasiliou, G., & Kamposiora, P. (2020). 3D printed complete removable dental prostheses: A narrative review. BMC Oral Health, 20(1), 1-9.

Arakawa, I., Husain, N. A.-H., Srinivasan, M., Maniewicz, S., Abou-Ayash, S., & Schimmel, M. (2022). Clinical outcomes and costs of conventional and digital complete dentures in a university clinic: A retrospective study. The journal of prosthetic dentistry, 128(3), 390-395.

Arslan, M., Murat, S., Alp, G., & Zaimoglu, A. (2018). Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures. Int J Comput Dent, 21(1), 31-40.

Atalay, S., Çakmak, G., Fonseca, M., Schimmel, M., & Yilmaz, B. (2021). Effect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatments. Journal of the mechanical behavior of biomedical materials, 121, 104646.

Atalay, S., Fonseca, M., Schimmel, M., & Yilmaz, B. (2022). Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials. The journal of prosthetic dentistry.

Ayman, A.-D. (2017). The residual monomer content and mechanical properties of CAD/CAM resins used in the fabrication of complete dentures as compared to heat cured resins. Electronic physician, 9(7), 4766.

Azmi, A. S., Nizal, N. A. B. A., Ismail, P. M. A., & Ngadiman, N. (2022). Study on Mechanical Properties of Organic and Non-Organic Fibre Panel Board. Multidisciplinary Applied Research and Innovation, 3(1), 266-281.

Babeer, W. A. (2025). Comparative Analysis of the Fracture Toughness in Different Brands of Milled Denture Base Materials. Bulletin of Stomatology and Maxillofacial Surgery, 21, 80-92.

Batisse, C., & Nicolas, E. (2021). Comparison of CAD/CAM and conventional denture base resins: A systematic review. Applied Sciences, 11(13), 5990.

Bhaduri, S. B., & Bhaduri, S. (2009). Biomaterials for Dental Applications. In Narayan (Ed.), Biomedical Materials (pp. 302). USA: Springer.

Bilgin, M. S., Baytaroğlu, E. N., Erdem, A., & Dilber, E. (2016). A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication. Eur J Dent, 10(2), 286-291.

Chen, Z., Tu, Q., Fang, Z., Shen, X., Yin, Q., Zhang, X., & Pan, M. (2022). Molecular Dynamics Studies of the Mechanical Behaviors and Thermal Conductivity of Polyisoprene with Different Degrees of Polymerization. Polymers, 14(22), 4950.

Chladek, G., Pakieła, K., Pakieła, W., Żmudzki, J., Adamiak, M., & Krawczyk, C. (2019). Effect of antibacterial silver-releasing filler on the physicochemical properties of poly (methyl methacrylate) denture base material. Materials, 12(24), 4146.

Choksi, R. H., & Mody, P. V. (2016). Flexural properties and impact strength of denture base resins reinforced with micronized glass flakes. J Indian Prosthodont Soc, 16(3), 264-270.

de Oliveira, E., Zancanaro de Figueiredo, E., Spohr, A. M., & Lima Grossi, M. (2021). Properties of acrylic resin for CAD/CAM: a systematic review and meta‐analysis of in vitro studies. Journal of Prosthodontics, 30(8), 656-664.

Deste, G., Durkan, R., Perihan, O., & Gürbüz, A. (2020). The effect of autoclave and heat polymerization techniques of internal adaptation of acrylic resins. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 30(4), 614-619.

Di Fiore, A., Meneghello, R., Brun, P., Rosso, S., Gattazzo, A., Stellini, E., & Yilmaz, B. (2022). Comparison of the flexural and surface properties of milled, 3D-printed, and heat polymerized PMMA resins for denture bases: An in vitro study. Journal of prosthodontic research, 66(3), 502-508.

Dimitrova, M., Corsalini, M., Kazakova, R., Vlahova, A., Chuchulska, B., Barile, G., . . . Kazakov, S. (2022). Comparison between conventional PMMA and 3D printed resins for denture bases: A narrative review. Journal of Composites Science, 6(3), 87.

Duymus, Z. Y., Ozdogan, A., Ulu, H., & Ozbayram, O. (2016). Evaluation the vickers hardness of denture base materials. Open journal of stomatology, 6(04), 114.

El-Shaheed, N. H., Lamfon, H. A., Salama, R., Faramawy, A. M. G., & Mostafa, A. Z. H. (2022). Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture. International Journal of Dentistry, 2022.

Forte, M. A., Silva, R. M., Tavares, C. J., & Silva, R. F. E. (2021). Is Poly(methyl methacrylate) (PMMA) a Suitable Substrate for ALD?: A Review. Polymers (Basel), 13(8).

Gibreel, M., Perea-Lowery, L., Lassila, L., & Vallittu, P. K. (2022). Mechanical Properties Evaluation of Three Different Materials for Implant Supported Overdenture: An In-Vitro Study. Materials, 15(19), 6858.

Hada, T., Kanazawa, M., Iwaki, M., Katheng, A., & Minakuchi, S. (2021). Comparison of mechanical properties of PMMA disks for digitally designed dentures. Polymers, 13(11), 1745.

Hashem, M., Alsaleem, S. O., Assery, M. K., Abdeslam, E. B., Vellappally, S., & Anil, S. (2014). A comparative study of the mechanical properties of the light-cure and conventional denture base resins. Oral Health Dent Manag, 13(2), 311-315.

Iwaki, M., Kanazawa, M., Arakida, T., & Minakuchi, S. (2020). Mechanical properties of a polymethyl methacrylate block for CAD/CAM dentures. Journal of Oral Science, 62(4), 420-422.

Jafarpour, D., Haricharan, P. B., & de Souza, R. F. (2024). CAD/CAM versus traditional complete dentures: A systematic review and meta‐analysis of patient‐and clinician‐reported outcomes and costs. Journal of Oral Rehabilitation.

Jandial, S., Gupta, R., Sharma, S., Mahajan, N., Kotwal, B., & Kharyal, S. (2017). Prevalence of Temporomandibular Disorders in Patients Wearing Complete Dentures Visiting Prosthodontics Department, Indira Gandhi Government Dental College, Jammu. INTERNATIONAL JOURNAL OF PREVENTIVE AND PUBLIC HEALTH SCIENCES, 3(2), 35-37.

Janeva, N. M., Kovacevska, G., Elencevski, S., Panchevska, S., Mijoska, A., & Lazarevska, B. (2018). Advantages of CAD/CAM versus conventional complete dentures-a review. Open access Macedonian journal of medical sciences, 6(8), 1498-1502.

Kamal, M. (2021). Evaluation of Surface Micro-hardness and Fracture Toughness of Conventionally Constructed versus CAD/CAM Constructed Denture Base Materials-an In-Vitro Study. Egyptian Dental Journal, 67(1-January (Fixed Prosthodontics, Removable Prosthodontics and Dental Materials)), 757-765.

Karthick, R., Sirisha, P., & Sankar, M. R. (2014). Mechanical and tribological properties of PMMA-sea shell based biocomposite for dental application. Procedia materials science, 6, 1989-2000.

Khan, A. A., Fareed, M. A., Alshehri, A. H., Aldegheishem, A., Alharthi, R., Saadaldin, S. A., & Zafar, M. S. (2022). Mechanical Properties of the Modified Denture Base Materials and Polymerization Methods: A Systematic Review. Int J Mol Sci, 23(10).

Kirad, A. S., Dugal, R., Godil, A. Z., Kazi, A. I., Madanshetty, P., & Attarwala, T. (2020). Evaluation of Flexural and Impact Strength of CAD–CAM and Two Different Conventional Denture Base Resins: An In Vitro Study. Evaluation, 10(2).

Klironomos, T., Katsimpali, A., & Polyzois, G. (2015). The effect of microwave disinfection on denture base polymers, liners and teeth: A Basic overview. Acta stomatologica Croatica, 49(3), 242.

Kosec, B., Vodlan, M., Karpe, K., Nagode, A., Bizjak, M., Kopač, I., . . . Gojić, M. (2018). Thermal properties of selected dental materials. Paper presented at the 12th Scientific-Research Symposium with International Participation: Metallic and Nonmetallic Materials: Production - Properties - Application, Travnik, Bosnia and Herzegovina.

Lee, D.-H., & Lee, J.-S. (2020). Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins. Journal of Dental Rehabilitation and Applied Science, 36(3), 183-195.

Longkumer, P., Jain, S., Bhasin, N., Singh, B., Borse, P., & Kaur, J. (2025). Comparative Evaluation of the Mechanical Properties of Denture Base Resins Fabricated Using Computer-Aided Design and Manufacturing, Three-Dimensional Printing, and Conventional Heat Polymerization Techniques: An In Vitro Study. Cureus, 17(6).

Malik, A. (2019). Flexural strength, fracture toughness, and denture tooth adhesion of computer aided milled and printed denture bases. The Ohio State University.

May, L. W., & Seong, L. G. (2018). A narrative review of different types and processing methods of acrylic denture base material. Annals of Dentistry University of Malaya, 25(2), 58-67.

McCabe, J. F., & Walls, A. W. G. (2008). Applied Dental Materials: Wiley.

Meng, T. R., & Latta, M. A. (2005). Physical properties of four acrylic denture base resins. J Contemp Dent Pract, 6(4), 93-100.

Mohd Farid, D. A., Zahari, N. A. f. H., Said, Z., Ghazali, M. I. M., Hao-Ern, L., Mohamad Zol, S., . . . Alauddin, M. S. (2022). Modification of Polymer Based Dentures on Biological Properties: Current Update, Status, and Findings. International Journal of Molecular Sciences, 23(18), 10426.

Murakami, N., Wakabayashi, N., Matsushima, R., Kishida, A., & Igarashi, Y. (2013). Effect of high-pressure polymerization on mechanical properties of PMMA denture base resin. Journal of the mechanical behavior of biomedical materials, 20, 98-104.

Nair, C., C Dathan, P., & Mohankumar, T. (2021). Resins for CAD/CAM Dentures. Acta Scientific Dental Scienecs, 5(4), 01-03.

Narayan, R. (2009). Biomedical Materials. USA: Springer Science & Business Media.

Neshati, A., Kouchak Dezfouli, N., Sadafi, M., & Omidi, S. (2021). Compressive Strength of Three Types of Heat-Cure Acrylic Resins: Acropars, Acrosun, and Meliodent. Journal of Research in Dental and Maxillofacial Sciences, 6(4), 14-17.

Nguyen, J.-F., Migonney, V., Ruse, N. D., & Sadoun, M. (2012). Resin composite blocks via high-pressure high-temperature polymerization. Dental Materials, 28(5), 529-534.

Ozkir, S. E., Yilmaz, B., Unal, S. M., Culhaoglu, A., & Kurkcuoglu, I. (2018). Effect of heat polymerization conditions and microwave on the flexural strength of polymethyl methacrylate. Eur J Dent, 12(1), 116-119.

Pacquet, W., Benoit, A., Hatège-Kimana, C., & Wulfman, C. (2019). Mechanical properties of CAD/CAM denture base resins. Int J Prosthodont, 32(1), 104-106.

Patel, R., Viswambaran, M., Gopi, A., Banari, A., & Mahesh, G. U. (2025). Comparative evaluation of the flexural strength and microhardness of conventionally polymerized, CAD-CAM milled, and 3D printed provisional crown and bridge materials: An in vitro study. International Journal of Applied Dental Sciences, 11(4), 175-180.

Perea-Lowery, L., Minja, I. K., Lassila, L., Ramakrishnaiah, R., & Vallittu, P. K. (2021). Assessment of CAD-CAM polymers for digitally fabricated complete dentures. The journal of prosthetic dentistry, 125(1), 175-181.

Pituru, S. M., Greabu, M., Totan, A., Imre, M., Pantea, M., Spinu, T., . . . Ionescu, E. (2020). A review on the biocompatibility of PMMA-based dental materials for interim prosthetic restorations with a glimpse into their modern manufacturing techniques. Materials, 13(13), 2894.

Pong, M. T., Grymak, A., Waddell, J. N., & Choi, J. J. E. (2022). Bond Strength between CAD/CAM PMMA Denture Base Resins and Characterisation Composites. Oral, 2(1), 75-87.

Prajwala, N., Kumar, C. R., Sujesh, M., Rao, D. C., & Pavani, L. (2020). Denture base reinforcing materials - A review. IP Annals of Prosthodontics and Restorative Dentistry, 6(2), 52-59.

Prpić, V., Schauperl, Z., Ćatić, A., Dulčić, N., & Čimić, S. (2020). Comparison of mechanical properties of 3D‐printed, CAD/CAM, and conventional denture base materials. Journal of Prosthodontics, 29(6), 524-528.

Punet, X., Mauchauffé, R., Rodríguez-Cabello, J. C., Alonso, M., Engel, E., & Mateos-Timoneda, M. A. (2015). Biomolecular functionalization for enhanced cell–material interactions of poly(methyl methacrylate) surfaces. Regenerative Biomaterials, 2(3), 167-175.

Punset, M., Brizuela, A., Pérez-Pevida, E., Herrero-Climent, M., Manero, J. M., & Gil, J. (2022). Mechanical characterization of dental prostheses manufactured with PMMA–graphene composites. Materials, 15(15), 5391.

Rahman, S. S., Mahmud, M. B., Monfared, A. R., Lee, P. C., & Park, C. B. (2023). Achieving outstanding toughness of PMMA while retaining its strength, stiffness, and transparency using in situ developed TPEE nanofibrils. Composites Science and Technology, 236, 109994.

Rajan, R., Vidhya, J., Azhagarasan, N., Jayakrishnakumar, S., & Ramakrishnan, H. (2022). Evaluation of the effect of titanium dioxide and gold nanoparticles surface treatment on the flexural strength of polymethyl methacrylate heat cure denture base resin. Journal of Clinical Advances in Dentistry, 6(1), 001-009.

Reeponmaha, T., Angwaravong, O., & Angwarawong, T. (2020). Comparison of fracture strength after thermo-mechanical aging between provisional crowns made with CAD/CAM and conventional method. The journal of advanced prosthodontics, 12(4), 218.

Saad, Y. M., Abdelhamid, A. M., & ElShabrawy, S. M. (2018). Laboratory evaluation of pre-polymerized denture base material used for CAD/CAM complete denture manufacturing. Alexandria Dental Journal, 43(3), 94-101.

Saleem, M., Saleem, R., Meshack, R. A., & Guru, R. (2011). Prosthetic management of edentulous mandible using endosseous implants and overdentures. J Contemp Dent Pract, 12(1357), 7.

Shah, J., Bulbule, N., Kulkarni, S., Shah, R., & Kakade, D. (2014). Comparative evaluation of sorption, solubility and microhardness of heat cure polymethylmethacrylate denture base resin & flexible denture base resin. J Clin Diagn Res, 8(8), Zf01-04.

Sherif, A. F., Helal, M. A., & Baraka, Y. A. E. (2023). Modulus of Elasticity of Different Resin Denture Base Materials: A Comparative Study. Al-Azhar Journal of Dental Science, 26(3), 277-281.

Srinivasan, M., Chien, E. C., Kalberer, N., Caravaca, A. M. A., Castelleno, A. L., Kamnoedboon, P., . . . Wismeijer, D. (2022). Analysis of the residual monomer content in milled and 3D-printed removable CAD-CAM complete dentures: an in vitro study. Journal of dentistry, 120, 104094.

Srinivasan, M., Gjengedal, H., Cattani-Lorente, M., Moussa, M., Durual, S., Schimmel, M., & Müller, F. (2018). CAD/CAM milled complete removable dental prostheses: An in vitro evaluation of biocompatibility, mechanical properties, and surface roughness. Dental materials journal, 37(4), 526-533.

Srinivasan, M., Kamnoedboon, P., McKenna, G., Angst, L., Schimmel, M., Özcan, M., & Müller, F. (2021). CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes. Journal of dentistry, 113, 103777.

Srivastava, R., Khandelwal, S., Makker, R., Razdan, R., Reddy, P., Bhogisetty, C., . . . Bhandi, S. (2023). Impact Strength of Various Types of Acrylic Resin: An In Vitro Study. The Journal of Contemporary Dental Practice, 24(1), 56-60.

Steinmassl, O., Offermanns, V., Stöckl, W., Dumfahrt, H., Grunert, I., & Steinmassl, P.-A. (2018). In vitro analysis of the fracture resistance of CAD/CAM denture base resins. Materials, 11(3), 401.

Suganna, M., Kausher, H., Tarek Ahmed, S., Sultan Alharbi, H., Faraj Alsubaie, B., Ds, A., . . . Meer Rownaq Ali, A. B. (2022). Contemporary Evidence of CAD-CAM in Dentistry: A Systematic Review. Cureus, 14(11), e31687.

Tieh, M. T., Waddell, J. N., & Choi, J. J. E. (2022). Optical and mechanical properties of conventional, milled and 3D-printed denture teeth. Journal of the mechanical behavior of biomedical materials, 126, 105061.

Tuna, E. B., Rohlig, B. G., Sancakli, E., Evlioglu, G., & Gencay, K. (2013). Influence of acrylic resin polymerization methods on residual monomer release. The Journal of Contemporary Dental Practice, 14(2), 259.

Ulmer, M. (2019). Biocompatibility and mechanical/physical properties of 3D printed, milled, and conventionally processed denture base materials. Augusta University.

Ulu, H., Yanikoglu, N., Sagsoz, N., & Ozdogan, A. (2021). Water Sorption of Polymethylmethacrylate and Polyamide Materials: A Comparative Study. International Journal of Prosthodontics and Restorative Dentistry, 11(1), 22-26.

Vashisht, P. S., & Arora, A. (2020). CLINICAL PROCEDURES FOR FABRICATION OF COMPLETE DENTURES USING CAD/CAM TECHNOLOGY: A REVIEW. Guident, 13(9).

Vásquez-Niño, A. F., Ochoa-Alzate, J. R., Osorio-Amariles, D., & Rodríguez-Quirós, H. A. (2021). Denture base polymers for analog and digital manufacturing: comparative study of the flexural strength, elastic modulus, and compressive strength of their mechanical properties. Revista Facultad de Odontología Universidad de Antioquia, 33(1), 6-16.

Wedekind, L., Güth, J.-F., Schweiger, J., Kollmuss, M., Reichl, F.-X., Edelhoff, D., & Högg, C. (2021). Elution behavior of a 3D-printed, milled and conventional resin-based occlusal splint material. Dental Materials, 37(4), 701-710.

Young, B. C. (2010). A comparison of polymeric denture base materials. University of Glasgow.

Youssef, A. (2019). Poly Methyle Metha Acrylate (PMMA) Properties & Manufacturing & Applications & Limitations. Department of chemical engineering, Higher technological institute-Tenth of Ramadan city, Egypt.

Yu, H.-J., Kang, Y.-J., Park, Y., Kim, H., & Kim, J.-H. (2024). A comparison of the mechanical properties of 3D-printed, milled, and conventional denture base resin materials. Dental materials journal, 43(6), 813-821.

Zafar, M. S. (2020). Prosthodontic applications of polymethyl methacrylate (PMMA): An update. Polymers, 12(10), 2299.

Zeidan, A., El-Rahim, A., & Helal, M. (2022). Evaluation For Elastic Modulus Of CAD-CAM Milled And 3D Printed Denture Base Resins. Al-Azhar Journal of Dental Science, 25(3), 241-246.

Zeidan, A. A. E., Abd Elrahim, R. A., Abd El Hakim, A. F., Harby, N. M., & Helal, M. A. (2022). Evaluation of Surface Properties and Elastic Modulus of CAD-CAM Milled, 3D Printed, and Compression Moulded Denture Base Resins: An In Vitro Study. Journal of International Society of Preventive and Community Dentistry, 12(6), 630-637.

Zhang, P., Ma, L., Fan, F., Zeng, Z., Peng, C., Loya, P. E., . . . Zhang, X. (2014). Fracture toughness of graphene. Nature communications, 5(1), 3782.

التنزيلات
منشور
2026-07-26
القسم
Reviw Study
الرخصة
Creative Commons License

هذا العمل مرخص بموجب Creative Commons Attribution-NonCommercial 4.0 International License.

كيفية الاقتباس

PMMA Denture Base Materials: A Review on Mechanical Properties of Conventional and CAD/CAM Milled Materials. (2026). Derna Academy Journal for Applied Sciences, 7(1), 56-73. https://doi.org/10.71147/nrpzh728

المؤلفات المشابهة

1-10 من 19

يمكنك أيضاً إبدأ بحثاً متقدماً عن المشابهات لهذا المؤلَّف.